Industrial valves—Pressure testing (English Version)
Project Category | Shell Test Requirements | Seal Test Requirements | Upper Seal Test Requirements |
---|---|---|---|
Test Medium | Liquid or gas, selected according to valve material | High-pressure liquid or gas | Same as shell test requirements |
Test Pressure | ≥1.5×CWP (liquid), ≥1.1×CWP (gas) | ≥1.1×CWP or 1.1 times of design pressure difference | ≥1.1×CWP |
Test time | ≥60 seconds (DN≤50), ≥120 seconds (DN≥150) | Depending on the nominal size, up to 300 seconds | Same as shell test requirements |
Shell test:Pressure test the overall structure of the valve to ensure no leakage and structural damage under rated pressure.
Seal test:Mainly verifies the sealing performance of the valve, applicable to important types of valves such as gate valves and ball valves.
Upper seal test:For valves with upper seal structure, test their sealing effect under high pressure.